    Red Team 1949  (formerly CHT Attack and Defense Team) In this rapidly changing Internet era, we maintain our original intention and create the best community to jointly exchange network technologies. You can obtain hacker attack and defense skills and knowledge in the forum, or you can join our Telegram communication group to discuss and communicate in real time. All kinds of advertisements are prohibited in the forum. Please register as a registered user to check our usage and privacy policy. Thank you for your cooperation.

    TheHackerWorld Official

Recommended Posts

现有一台HP DL580 G5服务器,应用突然中断,网络也连接不上,去机房查看,发现该服务器宕机,重启服务器后,开机自检屏幕无显示,诊断板上的内部组件灯亮,且四个CPU的告警灯也亮。断电后过两分钟开机,故障依旧。

由于该服务器安装有四个CPU,且服务器只能在安装有一个、两个、四个CPU的情况下运行,所以将三号和四号的CPU、CPU电压模块VRM拆下,可正常开机,进入操作系统后,使用HP软件查看硬件日志,发现日志中只记录POST ERROR,并未有详细的故障记录,且为了尽快恢复应用,并未详细测试拆下的CPU和VRM,在使用一号和二号CPU时,该服务器运行正常。

附1、HP DL580 G5服务器的诊断板位于开关的下部,光驱的上部;
附2、CPU告警可能为CPU、VRM、主板等故障引起,也可能散热不好,再次将三号、四号CPU装上,服务器可能可以正常开机自检运行。