    Red Team 1949  (formerly CHT Attack and Defense Team) In this rapidly changing Internet era, we maintain our original intention and create the best community to jointly exchange network technologies. You can obtain hacker attack and defense skills and knowledge in the forum, or you can join our Telegram communication group to discuss and communicate in real time. All kinds of advertisements are prohibited in the forum. Please register as a registered user to check our usage and privacy policy. Thank you for your cooperation.

    TheHackerWorld Official

Recommended Posts

开机出现F1和F2的提示通常都是由于Smart Array系列的阵列卡报警所致。

1. 1769-Slot X Drive Array – Drive(s) Disabled Due to Failure During Capacity Expansion.Select F1 to continue with logical drives disabled.Select F2 to accept data loss and to re-enable logical drives.

故障原因:阵列加速器模块被卸下或出现故障,扩展进程数据丢失;无法从阵列加速器中读取扩展进程数据;扩展因不可恢复的驱动器错误而终止;扩展因阵列加速器错误而终止。

解决方法:按F2键接受数据丢失并重新启用逻辑驱动器;从备份里恢复数据;如果是因驱动器质量有问题或阵列加速器故障而导致的,请更换相应的驱动器或阵列控制器。

2.1786-Slot 1 Drive Array Recovery Needed.Select F1 to continue with recovery of data to drive.Select F2 to continue without recovery of data to drive.

故障原因:系统处于临时数据恢复模式下。先前出现故障或更换的驱动器尚未重建。

解决方法:按F1键启动自动数据恢复程序,更换驱动器或驱动器工作时,数据自动恢复到驱动器X;按F2键使系统能够以临时数据恢复模式继续运行。

3.1788-Slot X Drive Array Reports Incorrect Drive Replacement.

故障原因:更换的驱动器被安装在不正确的驱动器托架上;也可能因驱动器电源线连接有问题、数据电缆噪音或 SCSI 电缆有缺陷而显示。

解决方法:按照指导重新正确的安装驱动器;如果此消息是因电源线连接有问题而不是驱动器更换不正确所致,检查电缆线路是否正确。

4. 1789-Slot X Drive Array SCSI Drive(s) Not Responding……Check cables or replace the following SCSI drives: SCSI Port Y: SCSI ID Z Select F1 to continue – drive array will remain disabled. Select F2 to failed drives that are not responding – Interim Recovery Mode will be enabled if configured for fault tolerance.

故障原因:上次在使用系统时工作的驱动器此时缺少或未启动。可能是驱动器出现问题或SCSI电缆松动。

解决方法:切断系统电源,检查电缆的连接并确保所有驱动器均已完全插入其驱动器托架中,打开服务器电源看问题是否依然存在,如果配置为可进行容错操作且RAID级别能承受指定的所有驱动器出现的故障,请按F2键废除不响应的驱动器,立刻更换为质量良好的驱动器,否则,按F1键启动在控制器上禁用所有逻辑驱动器的系统。

5.1799-Drive Array – Drive(s) Disabled Due to Array Accelerator Data Loss. Select “F1” to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives.

故障原因:逻辑驱动器因 posted-writes 内存中数据丢失而出现故障。

解决方法:按F1键且通过禁用逻辑驱动器来继续,或者按F2键接受数据丢失并重新启用逻辑驱动器。按F2键之后,检查文件系统的完整性并从备份中恢复丢失的数据。

开机出现SMART的报错信息

1720-Slot X Drive Array – S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID Z.

故障原因:这是预先通知SCSI硬盘驱动器不久将出现故障。

解决方法:如果配置为非RAID0阵列,请更换将出现故障/已经出现故障的驱动器;果配置为RAID0或非 RAID设置,请备份驱动器、更换或恢复。